
Low Residual Volume Syringe 2ml
Low Residual Volume Syringe 2ml is a high-precision medical disposable designed for dosage accuracy and minimal fluid retention. With a nominal capacity of 2.0 ml and a specialized dead-space reduction tip, this product is suitable for administering high-value biologicals, vaccines, and clinical therapeutics. Complete technical specifications, regulatory documentation, and volume quotation support are available for medical distributors, regional importers, and institutional buyers.
Key Features
Dead Space Reduction: An extended plunger tip fills the inner nozzle cavity to lower residual volume below 0.005 ml per injection.
High-Clarity Barrel: Transparent polypropylene construction allows instant visual check of fluid levels and air bubbles during filling.
Indelible Graduation Scale: High-contrast 0.1 ml scale markings ensure precise volumetric measurement without ink smudging.
Dual-Contact Gasket: Synthetic rubber seal provides smooth sliding friction while maintaining leak resistance under pressure.
Controlled Lubrication: Micro-dosed medical silicone oil coating prevents plunger sticking during slow manual injections.
Standard Connection: Compatible with standard hypodermic needles or configured with integrated low-dead-space needles.
Technical Specifications
|
Parameter |
Specification |
Standard / Method |
|
Nominal Volume |
2.0 ml |
ISO 7886-1 |
|
Graduation Interval |
0.1 ml |
ISO 7886-1 |
|
Dead Space Volume |
Less than or equal to 0.005 ml |
ISO 7886-1 Annex C |
|
Barrel / Plunger Material |
Medical-grade Polypropylene (PP) |
USP Class VI |
|
Gasket Material |
Isoprene Synthetic Rubber (Latex-Free) |
ISO 10993-10 |
|
Lubrication |
Silicone Oil (Less than or equal to 0.25 mg/cm2) |
ISO 7886-1 |
|
Connection Type |
Luer Lock / Luer Slip / Fixed Needle |
ISO 80369-7 |
|
Needle Options |
23G to 30G (8 mm - 38 mm) |
ISO 9626 |
|
Sterilization |
Ethylene Oxide (EO) Gas |
ISO 11135 |
|
Sterility Assurance Level |
10^-6 |
EN 556-1 |
|
Shelf Life |
5 Years |
Real-Time / Accelerated Aging |
Design and Construction
Zero-Dead-Space Geometry
The contoured rubber tip matches the internal shape of the syringe hub, leaving virtually no void space for liquid entrapment.
Phthalate-Free Polymers
Pure medical polypropylene components contain no DEHP, plasticizers, or heavy metal stabilizers.
Integrity Stop Ring
Molded inner ridge prevents unintentional plunger withdrawal during fluid draw or transportation.
Intended Use and Applications
High-Cost Drug Delivery: Prevents valuable pharmaceutical waste during administration of oncology formulations, biologics, and specialized fluids.
Mass Vaccination Programs: Increases total available doses per multi-dose vial by eliminating dead-space volume loss.
Aesthetic and Dermatology Procedures: Delivers precise micro-doses requiring tight volume control.
Pediatric and Critical Care: Enables accurate administration of small-volume therapeutics to sensitive patient groups.
Quality and Regulatory Information
Quality Systems: Manufactured in cleanroom facilities certified under ISO 13485 standards.
Regulatory Dossiers: Technical documentation available for CE Marking (MDR 2017/745) and FDA 510(k) submissions.
Batch Traceability: Unit packages, inner cartons, and outer cases carry matching lot numbers, manufacturing dates, and expiration dates.
Inline Quality Checks: Automated vision systems test scale clarity, particle contamination, and dimensional accuracy during assembly.
Packaging and Supply
|
Packaging Configuration |
Details |
|
Primary Packaging |
Individual Paper-Plastic Blister Pack or Polybag |
|
Inner Box |
100 Pieces / Box |
|
Master Carton |
1,800 or 2,000 Pieces / Export Carton |
|
Palletization |
Standard Export Palletization with Stretch Wrap |
Customization Options
Custom printing for blister paper, inner boxes, and outer cartons based on buyer specifications.
Customization of needle gauge, length, and wall thickness (regular, thin, ultra-thin).
Choices between peelable paper-plastic blisters and ribbon polybags according to market preference.
Customized graduation increments or dual scale markings available upon request.
FAQ
Q: How does a Low Residual Volume Syringe 2ml reduce drug loss compared to standard models?
A: Standard syringes retain fluid inside the nozzle neck after full compression. The modified plunger tip fills this internal cavity, reducing dead space volume from roughly 0.07 ml down to less than 0.005 ml per injection.
Q: What is the typical production lead time?
A: Standard manufacturing lead time is 25 to 35 days following packaging artwork approval and deposit receipt.
Q: Are sterile samples available for regulatory registration?
A: Yes, sterile samples and corresponding technical files are provided for laboratory testing and registration filings.
Q: Which sterilization process is utilized?
A: Products are routinely sterilized using Ethylene Oxide gas. Gamma irradiation processing can be arranged upon request.
Q: What shipping documents are provided for customs clearance?
A: Export shipments include Certificate of Analysis, Sterilization Certificate, ISO 13485 documentation, Declaration of Conformity, and Technical Data Sheets.
Q: What is the minimum order quantity for custom packaging?
A: Standard minimum order quantity for custom-printed packaging is 100,000 units. Neutral standard packaging is available for smaller order quantities.
Hot Tags: low residual volume syringe 2ml, China low residual volume syringe 2ml suppliers, manufacturers, factory, 1ml Low Dead Spcace Syringe With Fixed Needle, Auto Destructdestruct Syrings 0 05ml, Disposable Infusion Set, Enteral Syringe, Manual Safety Syringe 1ml, Oral Syringe
Send Inquiry
